quantify_scheduler.backends.qblox.constants

Constants for compilation to Qblox hardware.

Module Contents

IMMEDIATE_SZ_GAIN[source]

Size of gain instruction immediates in Q1ASM programs.

IMMEDIATE_MAX_WAIT_TIME[source]

Max size of wait instruction immediates in Q1ASM programs. Max value allowed by assembler is 2**16-1, but this is the largest that is a multiple of 4 ns.

IMMEDIATE_SZ_OFFSET[source]

Size of offset instruction immediates in Q1ASM programs.

REGISTER_SIZE[source]

Size of registers in Q1ASM programs.

NCO_PHASE_DEG_STEP_COARSE = 0.9[source]

The phase (in deg) corresponding to an increase of 1 in the course argument of the q1asm instructions related to the NCO phases.

NCO_PHASE_NUM_STEP_COARSE = 400[source]

The maximum value of the course argument of the nco phase instructions.

NCO_PHASE_DEG_STEP_FINE = 0.00225[source]

The phase (in deg) corresponding to an increase of 1 in the fine argument of the q1asm instructions related to the NCO phases.

NCO_PHASE_NUM_STEP_FINE = 400[source]

The maximum value of the fine argument of the nco phase instructions.

NCO_PHASE_DEG_STEP_U_FINE = 3.6e-07[source]

The phase (in deg) corresponding to an increase of 1 in the ultra-fine argument of the q1asm instructions related to the NCO phases.

NCO_PHASE_NUM_STEP_U_FINE = 6250[source]

The maximum value of the ultra-fine argument of the nco phase instructions.

GRID_TIME = 4[source]

Clock period of the sequencers. All time intervals used must be multiples of this value.

MIN_TIME_BETWEEN_ACQUISITIONS = 1000[source]

Minimum time between two acquisitions to prevent FIFO errors.

SAMPLING_RATE = 1000000000[source]

Sampling rate of the Qblox control/readout instruments.

PULSE_STITCHING_DURATION = 1e-06[source]

Duration of the individual pulses when pulse stitching is used.

NUMBER_OF_SEQUENCERS_QCM = 6[source]

Number of sequencers supported by a QCM in the latest firmware.

NUMBER_OF_SEQUENCERS_QRM = 6[source]

Number of sequencers supported by a QRM in the latest firmware.

MIN_MIXER_PHASE_ERROR_DEG[source]

Lowest phase shift that can be configured in the instruments for mixer corrections.

MAX_MIXER_PHASE_ERROR_DEG = 45[source]

Lowest phase shift that can be configured in the instruments for mixer corrections.

MIN_MIXER_AMP_RATIO = 0.5[source]

Lowest value the amplitude correction can be set to. N.B. This correction is defined as Q/I.

MAX_MIXER_AMP_RATIO = 2.0[source]

Highest value the amplitude correction can be set to. N.B. This correction is defined as Q/I.

NUMBER_OF_REGISTERS :int = 64[source]

Number of registers available in the Qblox sequencers.

GENERIC_IC_COMPONENT_NAME :str = generic[source]

Default name for the generic instrument coordinator component.